Linksys SPA9000 Administration Manual page 208

Voice system ip telephony system pstn voip gateway with integrated voice mail server ip phones
Hide thumbs Also See for SPA9000:
Table of Contents

Advertisement

Voice Setting
Calling Timers
Wait-for-Answer time
Call Limit
Dialing Parameters
Tone out on
Tone out off
DTMF power
Answer after
Dial out wait
Dial out battery threshold
Line Settings
Transmit Gain
Receive Gain
Linksys Voice System Administration Guide
The time in seconds that the SPA400 waits for the called party to
answer the call before terminating the call automatically
The maximum value is 100 seconds.
Default: 180
The maximum time that a call can continue before it is terminated
automatically
Default: 65535
The duration in milliseconds of each tone in a DTMF sequence
Default: 200
The number of milliseconds that elapses between successive digits in a
DTMF sequence
Default: 200
The power level in 0.1 dBm of the DTMF tones
Default: -130
The number of rings that occur before the SPA400 answers an
incoming call
The maximum value is 2 rings.
Default: 2
The number of milliseconds that elapse after the SPA400 seizes a
telephony port and before the SPA400 sends DTMF digits
Default: 400
The minimum voltage level that the SPA400 must detect on a
telelphony port before seizing a telephony port for an outbound call
Default: 20
The gain level that the SPA400 may use to increase or attenuate the
power level before transmitting to the telephony port
NOTE: Change this setting if remote call participants have trouble
hearing the LVS users. Make changes in increments of 3 dB; changes of
less than 3 dB will not have a perceptible impact.
Default: 0
The gain level that the SPA400 may use to increase or attenuate the
power level before receiving on the telephony port
NOTE: The default Receive Gain settings should be satisfactory in most
use cases. Unnecessary changes in Receive Gain can cause problems
with echo.
Default: 0