Using the Resync URL
The SPA9000 can be configured to automatically resynchronize its internal configuration state
to a remote profile periodically and on power up. The automatic resyncs are controlled by
configuring the desired profile URL into the device.
The SPA resynchronizes only when it is idle.
Note
SYNTAX:
http://spa-ip-addr/admin/resync?[[protocol://][server-name[:port]]/profile-pathname]
EXAMPLE:
http://192.168.2.217/admin/resync?tftp://192.168.2.251/spaconf.cfg
•
If no parameter follows /resync?, the Profile Rule setting from the Provisioning page is
used.
•
If no protocol is specified, TFTP is assumed. If no server-name is specified, the host that
requests the URL is used as server-name.
•
If no port is specified, the default port is used (69 for TFTP, 80 for HTTP, and 443 for
HTTPS).
•
The profile-path is the path to the new profile with which to resync.
Using the Reboot URL
You can use the Reboot URL to reboot the SPA9000.
The SPA9000 reboots only when it is idle.
Note
SYNTAX:
http://spa-ip-addr/admin/reboot
EXAMPLE:
http://192.168.2.217/admin/reboot
Linksys Voice System Administration Guide
Remote Provisioning Features
151