Ring Waveform
Ring Frequency
Ring Voltage
CWT Frequency
Voice tab > Regional page
Control Timer Values (sec) section
Hook Flash Timer Min
Hook Flash Timer Max
Callee On Hook Delay
Reorder Delay
Call Back Expires
Call Back Retry Intvl
Call Back Delay
VMWI Refresh Intvl
Linksys Voice System Administration Guide
Description
Waveform for the ringing signal: Sinusoid or Trapezoid.
Default: Trapezoid
Frequency of the ringing signal. Valid values are 10–100 (Hz).
Default: 0
Ringing voltage. 60–90 (V).
Default: 85
Frequency script of the call waiting tone. All distinctive CWTs are based
on this tone.
Default: 440@-10
Minimum on-hook time before off-hook qualifies as hook-flash. Less
than this the on-hook event is ignored. Range: 0.1–0.4 seconds.
Default: .1
Maximum on-hook time before off-hook qualifies as hook-flash. More
than this the on-hook event is treated as on-hook (no hook-flash event).
Range: 0.4–1.6 seconds.
Default: .9
Phone must be on-hook for at this time in sec before the SPA9000 tears
down the current inbound call. It does not apply to outbound calls.
Range: 0–255 seconds.
Default: 0
Delay after far end hangs up before reorder tone is played. 0 = plays
immediately, inf = never plays. Range: 0–255 seconds.
Default: 5
Expiration time in seconds of a call back activation. Range: 0–65535
seconds.
Default: 1800
Call back retry interval in seconds. Range: 0–255 seconds.
Default: 30
Delay after receiving the first SIP 18x response before declaring the
remote end is ringing. If a busy response is received during this time, the
SPA9000 still considers the call as failed and keeps on retrying.
Default: .5
Interval between VMWI refresh to the CPE.
Default: 0