3.4.2 MAIN MOTOR
Table 3-61. Troubleshooting for MAIN MOTOR
Step
Action and Question
Parts below can be the source of this error
• MAIN MOTOR
(p.279)
• HARNESS ASSY LVPS
• LVPS
(p.287)
• HVPS/MCU
(p.301)
MAIN Motor
1. Remove the Imaging Cartridge.
2. Close the COVER OPEN.
1
3. Turn on the main power.
4. Check for operating sound of the MAIN Motor.
♦
Does the MAIN Motor operate?
♦
2
Has the trouble been cleared?
HARNESS ASSY LVPS (1)
1.
Remove the SHIELD PLATE LVPS. (p.285)
2. Disconnect P/J41 from the LVPS.
3
(Refer to
"Connectors
(p.406)")
3. Disconnect P/J11 from the HVPS/MCU.
4. Check continuity between P/J41 ↔ P/J11.
Is there continuity in each wiring between P/J41 ↔ P/J11?
♦
HARNESS ASSY LVPS (2)
1.
Remove the SHIELD PLATE LVPS. (p.285)
2. Disconnect P/J42 from the LVPS.
4
(Refer to
"Connectors
(p.406)")
3. Disconnect P/J10 from the HVPS/MCU.
4. Check continuity between P/J42 ↔ P/J10.
♦
Is there continuity in each wiring between P/J42 ↔ P/J10?
LVPS
5
1.
Replace the LVPS. (p.287)
♦
Has the trouble been cleared?
Troubleshooting
Yes
No
(Chapter 4 Disassembly and
Assembly)
Go to Step 2
Go to Step 3
Problem
Go to Step 3
solved
Replace the
Go to Step 4
HARNESS
ASSY LVPS
Replace the
Go to Step 5
HARNESS
ASSY LVPS
Problem
Go to Step 6
solved
Troubleshooting for Individual Units
Table 3-61. Troubleshooting for MAIN MOTOR (continued)
Step
Action and Question
HVPS/MCU
6
1.
Replace the HVPS/MCU. (p.301)
♦
Has the trouble been cleared?
Revision C
Yes
No
Replace the
Problem
MAIN
solved
MOTOR
112
Confidential