EPSON EPL-N3000/AcuLaser M4000N
4.12.5 PWBA DUPLEX
Removal
1.
Remove the COVER LEFT. (p.353)
2.
Remove the COVER RIGHT. (p.354)
3.
Remove the COVER TOP. (p.346)
4.
Disconnect the connectors of the harness from the connectors (P/J50, P/J51, P/J52,
P/J53, P/J54) of the PWBA DUPLEX.
5.
Remove the two screws (gold, tapping, 8mm x1, gold, 6mm x1) securing the
PWBA DUPLEX to the COVER HSG DUP.
6.
Remove the PWBA DUPLEX
Disassembly and Assembly
PWBA DUPLEX
Figure 4- 148. PWBA DUPLEX Removal
Option Duplex
4)
Screw(A)
53 54
P/J50
5)
6)
COVER HSG DUP
Revision C
52
51
JG3605AB
347