EPSON EPL-N3000/AcuLaser M4000N

4.8.6 SENSOR FACE UP OPEN

Removal
1.
Remove the COVER REAR 500. (p.270)
2.
Remove the COVER REAR. (p.167)
3.
Remove the COVER LEFT. (p.169)
4.
Remove the COVER RIGHT. (p.168)
5.
Remove the COVER EXIT 500. (p.261)
6.
Remove the CHUTE UP EXIT, CHUTE LOW EXIT. (p.263)
7.
Disconnect the connector (P/J291) of the HARNESS ASSY EXIT SNR from the
SENSOR FACE UP OPEN.
8.
Lift the CHUTE LOW EXIT, release the hook of the SENSOR FACE UP OPEN,
and remove the SENSOR FACE UP OPEN from the CHUTE LOW EXIT.
Installation
1.
Install the SENSOR FACE UP OPEN to the CHUTE LOW EXIT.
2.
Connect the connector (P/J291) of the HARNESS ASSY EXIT SNR to the
SENSOR FACE UP OPEN.
3.
Install the CHUTE UP EXIT, CHUTE LOW EXIT. (p.263)
4.
Install the COVER EXIT 500. (p.261)
5.
Install the COVER RIGHT. (p.168)
6.
Install the COVER LEFT. (p.169)
7.
Install the COVER REAR. (p.167)
Pay attention to the difference between the two types of screws and
C A U T I O N
use them at their correct positions respectively.
8.
Install the COVER REAR 500. (p.270)