6:5
PRP
PLB Request Priority
PRP controls the request priority for PLB
11 Highest
accesses.
10 Next highest
01 Next highest
00 Lowest
4
PGMAE
PLB Guarded Memory Access Enable
PGMAE controls whether PLB accesses
o
Bridge PLB master memory accesses
are guarded or unguarded.
are unguarded.
1 Bridge PLB master memory accesses
are guarded.
3
PAPM
PCI Arbiter Park Mode
PAPB defines how the internal PCI arbiter
o
The arbiter parks on requester 0 (the
handles bus parking.
bridge PCI master).
1 The arbiter parks on the last master
granted the bus.
2:1
PTMRCI
PCI Target Memory Read Command
PTMRCI enables the PCI bridge to be
Interpretation
forced to treat a PCI memory read as a
00 Memory Read
memory read multiple, or as a memory
01 Memory Read Line
read line, with respect to the burst size
10 Memory Read Multiples
implied by the read commands. This is for
11 Reserved
masters that use memory read for multiple
beat bursts.
0
APLRM
Atomic PLB Line Read Mode
APLRM controls the behavior of the
0
bridge PLB slave with respect to PLB line
1 PLB slave asserts Addrack and begins
reads. APLRM must not be se t to 1
its data tenure immediately after the PCI
unless all PCI target devices can
master receives the first read data word.
guarantee no disconnects for PLB line
reads.
17.5.3.27 PLB Slave Error Syndrome Register 0 (PCICO_PLBBESRO)
PCICO_PLBBESRO stores information about errors reported by the PCI bridge PLB slave. There are
four groups of errors, one each for PLB masters 0-3. PCICO_PLBBESRO[MxET] fields (x represents
a particular PLB master ID) contain information about the type of error. PCI parity errors set
PCICO_PLBBESRO[MxET] to Ob001. Master and target aborts set PCICO_PLBBESRO[MxET] to
Ob101 (non-configured bank error). The PCICO_PLBBESRO[MxRWS] fields show whether the
transaction causing the error was a read or write.
Each error field can be locked by PCICO_PLBBESRO[MxFL], which is set by a PLB lock error signal to
the bridge PLB slave. If the PCICO_PLBBESRO[MxFL] field associated with a master is 0, the PLB
lock error signal is driven high to the bridge PLB slave, and an error associated with that master
occurs. The error is then reported, and PCICO_PLBBESRO[MxFL] is set. Subsequent errors do not
set PCICO_PLBBESRO fields for that master until PCICO_PLBBESRO[MxFL] is cleared. If
PCICO_PLBBESRO[MxFL] = 0, and the PLB lock error Signal is low, the error is reported, and
PCICO_PLBBESRO[MxFL] is not set. Additional errors are also reported. Only software can clear
PCICO_PLBBESRO[MxFL].