Removing A 3.5-Inch Hdd Module; Installing A 3.5-Inch Dummy Module; Concluding Steps - Fujitsu PRIMERGY RX1330 M1 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY RX1330 M1:
Table of Contents

Advertisement

7.3.3.2

Removing a 3.5-inch HDD module

Ê Pinch the green locking clips and open the locking lever (see figure 79).
Ê Pull the HDD module out a few centimeters.
Ê Wait about 30 seconds to allow the hard disk drive to spin down.
I
This period is necessary for the RAID controller to recognize that an
HDD module has been removed and for the hard disk drive to come
to a stop.
Ê Pull the HDD module completely out of its bay.
7.3.3.3

Installing a 3.5-inch dummy module

V
CAUTION!
If the removed HDD module is not replaced immediately, always replace
a dummy module into the unused HDD bay to comply with applicable
EMC regulations and satisfy cooling requirements.
Figure 81: Installing the 3.5-inch dummy module
Ê Push the dummy module into the empty bay until it engages.
7.3.3.4

Concluding steps

No steps needed.
RX1330 M1
Upgrade and Maintenance Manual
Hard disk drives / solid state drives
145

Advertisement

Table of Contents
loading

Table of Contents