Show Port Inlinepower; Set Port Inlinepower - Enterasys D-Series Cli Reference Manual

Enterasys networks ethernet switch owner's manual
Table of Contents

Advertisement

Example
This example shows how to enable inline power trap messaging on module 1:
D2(su)->set inlinepower trap enable 1

show port inlinepower

Use this command to display all ports supporting PoE. 
Syntax
show port inlinepower [port-string]
Parameters
port‐string
Defaults
If not specified, information for all PoE ports will be displayed.
Mode
Switch command, read‐only.
Example
This example shows how to display PoE information for port fe
administrative state, PoE priority and class have not been changed from default values:
D2(su)->show port inlinepower
Port
----
fe
.2.1

set port inlinepower

Use this command to configure PoE parameters on one or more ports.
Syntax
set port inlinepower port-string {[admin {off | auto}] [priority {critical | high
| low}] [type type]}
Parameters
port‐string
admin off | auto
priority critical | 
high | low
type type
Defaults
None.
(Optional) Displays information for specific PoE port(s).
Type
Admin
Oper
----
-----
----
wireless
auto
searching
Specifies the port(s) on which to configure PoE.
Sets the PoE administrative state to off (disabled) or auto (on).
Sets the port(s) priority for the PoE allocation algorithm to critical 
(highest), high or low.
Specifies a string describing the type of device connected to a port.
fe
.2.1
Priority
--------
low
show port inlinepower
. In this case, the port's 
.2.1
Class
Power(W)
-----
--------
0
15.4
Enterasys D-Series CLI Reference 4-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents