Clear Cos Settings; Show Cos Settings - Enterasys D-Series Cli Reference Manual

Enterasys networks ethernet switch owner's manual
Table of Contents

Advertisement

clear cos settings

ToS
This value can be set per class of service, but is not required. When a frame is assigned to a 
class of service for which this value is configured, the ToS field of the incoming IP packet will 
be overwritten to the user‐defined value. All but the last two bits of the ToS field are 
rewritable. ToS can be set for CoS indexes 0 through 7.
IRL Reference
The CoS IRL reference field is optional, as rate limits are not required. The IRL reference does 
not assign an inbound rate limit but points to the CoS IRL Reference Mapping Table. This 
reference may be thought of as the virtual rate limiter that will assign the physical rate limiter 
defined by the IRL Reference Mapping Table.
Example
This example shows how to create CoS entry 8 with a priority value of 3:
D2(rw)->set cos settings 8 priority 3
clear cos settings
Use this command to clear Class of Service entry settings.
Syntax
clear cos settings cos-list {[all] | [priority] [tos-value] [irl-reference]}
Parameters
cos‐list
all
priority 
tos‐value
irl‐reference
Defaults
None.
Mode
Switch command, read‐write.
Example
This example shows how to clear the priority for CoS entry 8:
D2(rw)->clear cos settings 8 priority

show cos settings

Use this command to display Class of Service parameters.
Syntax
show cos settings [cos-list]
11-22 Policy Classification Configuration
Specifies a Class of Service entry to clear.
Clears all settings associated with this entry.
Clears the priority value associated with this entry.
Clears the Type of Service value associated with this entry.
Clear the IRL reference associated with this entry.

Hide quick links: