timeout timeout
server ip_address
port server‐secret
Mode
Switch command, read‐write.
Defaults
None.
Examples
This example shows how to enable the RADIUS accounting client for authenticating with the
accounting server at IP address 10.2.4.12, UDP authentication port 1800. As previously noted, the
"server secret" password entered here must match that already configured as the Read‐Write (rw)
password on the RADIUS accounting server:
D2(su)->set radius accounting server 10.2.4.12 1800
Enter secret:
Re-enter secret:
This example shows how to set the RADIUS accounting timeout to 30 seconds:
D2(su)->set radius accounting timeout 30
This example shows how to set RADIUS accounting retries to 10:
D2(su)->set radius accounting retries 10
clear radius accounting
Use this command to clear RADIUS accounting configuration settings.
Syntax
clear radius accounting {server ip-address | retries | timeout | counter}
Parameters
server ip‐address
retries
timeout
counter
Mode
Switch command, read‐write.
Sets the maximum amount of time (in seconds) to establish contact with a
specified RADIUS accounting server before timing out. Valid timeout
values are 1 ‐ 30.
Specifies the accounting server's:
•
IP address
•
UDP authentication port (0 ‐ 65535)
•
server‐secret (Read‐Write password to access this accounting server.
Device will prompt for this entry upon creating a server instance, as
shown in the example below.)
Clears the configuration on one or more accounting servers.
Resets the retries to the default value of 3.
Resets the timeout to 5 seconds.
Clears counters.
clear radius accounting