AT&T MERLIN LEGEND Release 3.1 System Programming Manual page 666

Communications system
Hide thumbs Also See for MERLIN LEGEND Release 3.1:
Table of Contents

Advertisement

Automatic Route Selection
Facility Restriction Level
Use this procedure to assign a Facility Restriction Level (FRL) to each route. The
FRL ranges from 0 (least restrictive) to 6 (most restrictive) and is used to restrict
user access to the route. The FRL assigned to telephones and remote access
users is the opposite of the FRL assigned to routes, where 0 is the most
restrictive and 6 is the least restrictive.
NOTE:
Pool routes must be programmed before you assign Facility Restriction
Levels.
Facility Restriction Levels are assigned to Tables 1 through 18. Tables 17 and
18, the Default Toll and Default Local tables respectively, cannot be changed.
Summary: Facility Restriction Level
Programmable by
Mode
Idle Condition
Planning Form
Factory Setting
Valid Entries
Inspect
Copy Option
Console Procedure
PC Procedure
Procedure: Facility Restriction Level
Console Display/Instructions
1
Select the Tables menu.
4–294
Programming Procedures
System manager
Hybrid/PBX
Not required
Form 3f, Automatic Route Selection Tables
Form 3g, Automatic Route Selection Default and Special
Numbers Tables
3 (beginning with Release 3.1, Table 18, the Default Local
table has a factory setting of 2)
0 to 6
No
No
table no, and pool route no.
or
route no.
Type restriction level
Additional Information
_
or More and
Dial restriction level
and
Type table no. and pool
Dial
PC

Advertisement

Table of Contents
loading

This manual is also suitable for:

Merlin legend 4.0

Table of Contents