Battery-Backed Cache Module - HP StorageWorks 500 Generation 2 Maintenance And Service Manual

Table of Contents

Advertisement

Battery-Backed Cache Module

To remove the component:
1. Determine if the controller configuration supports hot-plug cache
2. Remove the controller ("Modular Smart Array 500 Generation 2 Controller"
3. Remove the existing cache module.
4. Repeat steps 2 and 3 if the storage system has redundant controllers and the
To replace the cache module:
1. Install the module in the slot.
replacement:
If the storage system is equipped with a single controller, power down
the storage system (on page 9).
If the system has redundant controllers and the replacement cache is a
different capacity than the failed cache, power down the storage system
(on page 9).
If the system has redundant controllers and the replacement cache is the
same capacity as the failed cache, proceed with step 2.
on page 13).
replacement cache is a different capacity than the failed cache.
Removal and Replacement Procedures
15

Advertisement