Diagnostic Monitor - Cisco Catalyst 3560X-24P Command Reference Manual

Cisco ios release 12.2(55)se
Hide thumbs Also See for Catalyst 3560X-24P:
Table of Contents

Advertisement

diagnostic monitor

diagnostic monitor
Use the diagnostic monitor global configuration command to configure health-monitoring diagnostic
testing. Use the no form of this command to disable testing and to return to the default settings.
Syntax Description
interval
switch number
test
name
test-id
test-id-range
all
hh:mm:ss
milliseconds
day
syslog
Catalyst 3750-X and 3560-X Switch Command Reference
2-146
diagnostic monitor interval switch number test {name | test-id | test-id-range | all} hh:mm:ss
milliseconds day
diagnostic monitor switch number test {name | test-id | test-id-range | all}
diagnostic monitor syslog
diagnostic monitor threshold switch number test {name | test-id | test-id-range | all} failure count
count
no diagnostic monitor interval switch number test {name | test-id | test-id-range | all}
no diagnostic monitor switch number test {name | test-id | test-id-range | all}
no diagnostic monitor syslog
no diagnostic monitor threshold switch number test {name | test-id | test-id-range | all} failure
count count
Configure the interval between tests.
Specify the switch number, which is the stack member number. If the
switch is a standalone switch, the switch number is 1. If the switch is in a
stack, the range is 1 to 9, depending on the switch member numbers in the
stack.
This keyword is supported only on on stacking-capable switches.
Specify the tests to be run.
Specify the name of the test. For more information, see the "Usage
Guidelines" section.
Specify the ID number of the test. The range is from 1 to 7. For more
information, see the "Usage Guidelines" section.
Specify more than one test with the range of test ID numbers. For more
information, see the "Usage Guidelines" section.
Specify all of the diagnostic tests.
Configure the monitoring interval in hours, minutes, and seconds. For
formatting information, see the "Usage Guidelines" section.
Configure the monitoring interval in milliseconds (ms). The range is from
0 to 999 ms.
Configure the monitoring interval in the number of days. The range is from
0 to 20 days. For formatting information, see the "Usage Guidelines"
section.
Enable the generation of a syslog message when a health-monitoring test
fails.
Chapter 2
Catalyst 3750-X and 3560-X Switch Cisco IOS Commands
OL-21522-02

Advertisement

Table of Contents
loading

Table of Contents