system env temperature threshold yellow

system env temperature threshold yellow
Use the system env temperature threshold yellow global configuration command on the switch stack
or on a standalone switch to configure the difference between the yellow and red temperature thresholds
that determines the value of yellow threshold. Use the no form of this command to return to the default
value.
Syntax Description
value
Defaults
These are the default values:
Table 2-55
Switch
Catalyst 3750-X and Catalyst 3560-X
1. You cannot configure the red temperature threshold.
Command Modes
Global configuration
Command History
Release
12.2(53)SE2
Usage Guidelines
You cannot configure the green and red thresholds but can configure the yellow threshold. Use the
system env temperature threshold yellow value global configuration command to specify the
difference between the yellow and red thresholds and to configure the yellow threshold. For example, if
the red threshold is 60 degrees C and you want to configure the yellow threshold as 51 degrees C, set the
difference between the thresholds as 15 by using the system env temperature threshold yellow 9
command.
Note
The internal temperature sensor in the switch measures the internal system temperature and might vary
±5 degrees C.
Catalyst 3750-X and 3560-X Switch Command Reference
2-904
system env temperature threshold yellow value
no system env temperature threshold yellow value
Specify the difference between the yellow and red threshold values (in Celsius). The
range is 10 to 25. The default value is 14.
Default Values for the Temperature Thresholds
Modification
This command was introduced.
Chapter 2 Catalyst 3750-X and 3560-X Cisco IOS Commands
Difference
between Yellow
1
and Red
Red
14°C
60°C