Environmental Ranges
Operating temperature
Storage temperature
Relative humidity
Operating altitude
Storage altitude
Physical Specifications
OL-19593-01
Switch Specifications, page A-1
Power Supply Module Specifications, page A-2
Fan Module Specifications, page A-4
Environmental and Physical Specifications
A P P E N D I X
32 to 113° F (0 to 45° C)
–13 to 158° F (–25 to 70° C)
10 to 85% (noncondensing)
Up to 10,000 ft (3049 m)
Up to 15,000 ft (4573 m), NEBS up to 13,000 ft (4000 m)
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
A
A-1

Advertisement

loading

Summary of Contents for Cisco Catalyst 3560-X-24T

  • Page 1: Technical Specifications

    32 to 113° F (0 to 45° C) –13 to 158° F (–25 to 70° C) 10 to 85% (noncondensing) Up to 10,000 ft (3049 m) Up to 15,000 ft (4573 m), NEBS up to 13,000 ft (4000 m) Catalyst 3750-X and 3560-X Switch Hardware Installation Guide...
  • Page 2: Power Supply Module Specifications

    Environmental Ranges Operating temperature Storage temperature Relative humidity Altitude Physical Specifications Catalyst 3750-X and 3560-X Switch Hardware Installation Guide Environmental and Physical Specifications (continued) 15.6 lb (7.1 kg) 15.8 lb (7.2 kg) 16.3 lb (7.4 kg) 16.5 lb (7.5 kg) 16.7 lb (7.6 kg)
  • Page 3 Total output BTU 1. The total input and total output BTU ratings refer to input power to the power supply and output power to the switch. The BTU ratings are based on 100 VAC for the 350-W and 715-W power supplies and 115 VAC for the 1100-W power supply.
  • Page 4: Fan Module Specifications

    Wire gauge for ground connection Branch circuit protection 1. The total input and total output BTU ratings refer to input power to the power supply and output power to the switch. The BTU ratings are based on –36 VDC. Fan Module Specifications...
  • Page 5 VCCI Class A AS/NZS CISPR22 Class A China EMC certifications GOST Reduction of Hazardous Substances (ROHS) 5 Office product spec: 48 dBA at 86º F (30º C) CLEI code Catalyst 3750-X and 3560-X Switch Hardware Installation Guide Fan Module Specifications...
  • Page 6 Appendix A Technical Specifications Fan Module Specifications Catalyst 3750-X and 3560-X Switch Hardware Installation Guide OL-19593-01...