Cisco Catalyst 3560X-24P Command Reference Manual page 772

Cisco ios release 12.2(55)se
Hide thumbs Also See for Catalyst 3560X-24P:
Table of Contents

Advertisement

show power inline
Gi3/0/9
Gi3/0/10
<output truncated>
This is an example of output from the show power inline police command on a Catalyst 3750-X switch.
Table 2-47
Switch> show power inline police
Module
------
1
3
Interface State
--------- ------ ----------- ---------- ---------- ------ ------
Gi1/0/1
Gi1/0/2
Gi1/0/3
Gi1/0/4
Gi1/0/5
Gi1/0/6
Gi1/0/7
Gi1/0/8
Gi1/0/9
Gi1/0/10
Gi1/0/11
Gi1/0/12
Gi1/0/13
<output truncated>
In the previous example:
The Gi1/0/1 port is shut down, and policing is not configured.
The Gi1/0/2 port is shut down, but policing is enabled with a policing action to generate a syslog
message.
The Gi1/0/3 port is shut down, but policing is enabled with a policing action is to shut down the port.
Device detection is disabled on the Gi1/0/4 port, power is not applied to the port, and policing is
disabled.
Device detection is disabled on the Gi1/0/5 port, and power is not applied to the port, but policing
is enabled with a policing action to generate a syslog message.
Device detection is disabled on the Gi1/0/6 port, and power is not applied to the port, but policing
is enabled with a policing action to shut down the port.
The Gi1/0/7 port is up, and policing is disabled, but the switch does not apply power to the connected
device.
The Gi1/0/8 port is up, and policing is enabled with a policing action to generate a syslog message,
but the switch does not apply power to the powered device.
The Gi1/0/9 port is up and connected to a powered device, and policing is disabled.
The Gi1/0/10 port is up and connected to a powered device, and policing is enabled with a policing
action to generate a syslog message. The policing action does not take effect because the real-time
power consumption is less than the cutoff value.
The Gi1/0/11 port is up and connected to a powered device, and policing is enabled with a policing
action to generate a syslog message.
Catalyst 3750-X and 3560-X Switch Command Reference
2-740
NO
NO
describes the output fields.
Available
Used
(Watts)
(Watts)
---------
--------
370.0
0.0
865.0
864.0
Admin
Oper
Admin
State
Police
auto
off
none
auto
off
log
auto
off
errdisable n/a
off
off
none
off
off
log
off
off
errdisable n/a
auto
off
none
auto
off
log
auto
on
none
auto
on
log
auto
on
log
auto
on
errdisable ok
auto
errdisable
errdisable n/a
Chapter 2 Catalyst 3750-X and 3560-X Cisco IOS Commands
0.0
0.0
Remaining
(Watts)
---------
370.0
1.0
Oper
Cutoff Oper
Police
Power
n/a
n/a
n/a
5.4
5.4
n/a
n/a
n/a
5.4
5.4
n/a
n/a
n/a
5.4
n/a
n/a
ok
5.4
log
5.4
5.4
5.4
Power
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
5.1
4.2
5.9
4.2
0.0
OL-21522-02

Advertisement

Table of Contents
loading

Table of Contents