Chapter 2 Catalyst 3750-X and 3560-X Cisco IOS Commands
The Gi1/0/12 port is up and connected to a powered device, and policing is enabled with a policing
action to shut down the port. The policing action does not take effect because the real-time power
consumption is less than the cutoff value.
The Gi1/0/13 port is up and connected to a powered device, and policing is enabled with a policing
action to shut down the port.
This is an example of output from the show power inline police interface-id command on a standalone
switch.
Switch> show power inline police gigabitethernet0/4
Interface Admin
--------- ------ ---------- ---------- ---------- ------ -----
Gi0/4
Table 2-47
Field
Available
Used
Remaining
Admin State
Oper State
Admin Police
Oper Police
OL-21522-02
Table 2-47
describes the output fields.
Oper
Admin
State
State
Police
auto
power-deny log
show power inline police Field Descriptions
Description
The total amount of configured power
The amount of configured power allocated to PoE ports in watts.
The amount of configured power in watts that is not allocated to ports in the
system. (Available – Used = Remaining)
Administration mode: auto, off, static.
Operating mode:
errdisable—Policing is enabled.
faulty—Device detection on a powered device is in a faulty state.
off—No PoE is applied.
on—The powered device is detected, and power is applied.
power-deny—A powered device is detected, but no PoE is available, or the
real-time power consumption exceeds the maximum power allocation.
The operating mode is the current PoE state for the specified PoE port,
Note
the specified stack member, or for all PoE ports on the switch.
Status of the real-time power-consumption policing feature:
errdisable—Policing is enabled, and the switch shuts down the port when the
real-time power consumption exceeds the maximum power allocation.
log—Policing is enabled, and the switch generates a syslog message when
the real-time power consumption exceeds the maximum power allocation.
none—Policing is disabled.
Policing status:
errdisable—The real-time power consumption exceeds the maximum power
allocation, and the switch shuts down the PoE port.
log—The real-time power consumption exceeds the maximum power
allocation, and the switch generates a syslog message.
n/a—Device detection is disabled, power is not applied to the PoE port, or no
policing action is configured.
ok—Real-time power consumption is less than the maximum power
allocation.
Oper
Cutoff Oper
Police
Power
Power
n/a
4.0
0.0
1
on the switch in watts (W).
Catalyst 3750-X and 3560-X Switch Command Reference