Show Logging Onboard - Cisco Catalyst 3560X-24P Command Reference Manual

Cisco ios release 12.2(55)se
Hide thumbs Also See for Catalyst 3560X-24P:
Table of Contents

Advertisement

show logging onboard

show logging onboard
Use the show logging onboard privileged EXEC command to display the on-board failure logging
(OBFL) information.
Syntax Description
module [switch-number]
clilog
environment
message
poe
temperature
uptime
voltage
continuous
summary
start hh:mm:ss day month
year
end hh:mm:ss day month year (Optional) Display the data up to the specified time and date. For more
detail
Catalyst 3750-X and 3560-X Switch Command Reference
2-662
show logging onboard [module [switch-number]] {{clilog | environment | message | poe |
temperature | uptime | voltage} [continuous | detail | summary] [start hh:mm:ss day month
year] [end hh:mm:ss day month year]} [ | {begin | exclude | include} expression]
Chapter 2 Catalyst 3750-X and 3560-X Cisco IOS Commands
(Optional) Display OBFL information about the specified switches.
On Catalyst 3750-X switches, use the switch-number parameter to
specify the switch number, which is the stack member number. If the
switch is a standalone switch, the switch number is 1. If the switch is
in a stack, the range is 1 to 9, depending on the switch member numbers
in the stack.
On Catalyst 3560-X switches, the switch-number parameter is
always 1.
For more information about this parameter, see the "Usage Guidelines"
section for this command.
Display the OBFL CLI commands that were entered on the standalone
switch or specified stack members.
Display the unique device identifier (UDI) information for the
standalone switch or specified stack members and for all the connected
FRU devices: the product identification (PID), the version
identification (VID), and the serial number.
Display the hardware-related system messages generated by the
standalone switch or specified stack members.
Display the power consumption of PoE ports on the standalone switch
or specified stack members.
Display the temperature of the standalone switch or specified stack
members.
Display the time when the standalone switch or specified stack
members start, the reason the standalone switch or specified members
restart, and the length of time the standalone switch or specified stack
members have been running since they last restarted.
Display the system voltages of the standalone switch or the specified
switch stack members.
(Optional) Display the data in the continuous file.
(Optional) Display the data in the summary file.
(Optional) Display the data from the specified time and date. For more
information, see the "Usage Guidelines" section.
information, see the "Usage Guidelines" section.
(Optional) Display both the continuous and summary data.
OL-21522-02

Advertisement

Table of Contents
loading