"Charging Stopped Check Charging Source"
Cause
Problem in power supply
from external power source
AC charger has stopped
charging
AC charger is not compatible
with vehicle
9-2. If a warning is indicated on the meter
Remedy
Check the following items.
Plug is not disconnected
Plug is securely inserted
Remote switch is not off
Power source indicator on the CCID (Charging Circuit
Interrupting Device) is illuminated
The circuit breaker has tripped
Extension cord is not used and electrical socket is not
overloaded
Connected to a dedicated power line
Electrical leakage has occurred or not
If there is no problem with any of the above items, there may
be a problem with the electrical socket of the building.
Contact an electrician and request an inspection. (Contact
the facility manager of the charging station when there is a
problem with charging station.)
If charging cannot be carried out, even though there is no
problem with the power source path, there may be a mal-
function in the system. Have the vehicle inspected by your
Lexus dealer.
Furthermore, if the error warning indicator on the CCID
(Charging Circuit Interrupting Device) is flashing, there
may be an electrical leakage. Consult your Lexus dealer.
Charging may be canceled by an interruption of power
supply depending on specifications of a charger. Refer to
the instructions provided with the charger.
When charging is stopped using the charger
Equipment with charging schedule function
Equipment that is not compatible with the charging
schedule function of the vehicle
Check if it is possible to charge with the AC charging cable
equipped to the vehicle (if equipped). If charging cannot be
carried out, even when using the genuine AC charging
cable, contact your Lexus dealer.
Check if it is possible to charge with the AC charging cable
equipped to the vehicle.
If charging cannot be carried out, even when using the gen-
uine AC charging cable, consult your Lexus dealer.
491