Running An On-Hook Caller Id Test - Fluke 990DSL User Manual

Copperpro series ii broadband loop tester
Table of Contents

Advertisement

Running an On-Hook Caller ID Test

The On-Hook Caller ID test enables the tester to receive a call on the test line
from another line, then capture and display Caller ID calling party information.
1. Select the On-Hook Caller ID function and then press L.
The tester waits indefinitely (in an on-hook condition) for an incoming
phone call, which must be placed from another POTS line to the POTS
line under test.
If the test line is equipped with the Caller ID feature, the tester detects the
incoming Caller ID information (sent by the C.O. switch) after the first
ringing interval. It then displays the received Phone number along with the
associated Name, Date, and Message (if included).
2. Press A(
Timing Details
Ringing Duration
Ringing to CD (Carrier Detection) Delay
CD to Seizure Delay
Seizure Duration
Seizure Bytes
Mark (frequency) Duration
Data Duration
Data Bytes
3. Press B(
Raw Data)
If the test line was not equipped with the Caller ID feature, the tester continues
to wait until you press M. If the CID data was garbled, the tester displays an
error message after the first ringing interval.
POTS Testing and Fault Location
) to view the following CID signal information:
to view the raw hexadecimal CID data digits.
Dial-Up Test Group
4
4-57