Tutorial: Running An Otdr Test; Required Equipment - Fluke OF-500-01 OptiFiber Technical Reference Handbook

Of-500 series optifiber
Hide thumbs Also See for OF-500-01 OptiFiber:
Table of Contents

Advertisement

Tutorial: Running an OTDR Test

The tutorial in this section familiarizes you with the tester
by guiding you through the following tasks:
Using the tester's menu system
Connecting the tester to a cable
Running an OTDR test
Viewing the results in several levels of detail
Saving bi-directional test results

Required Equipment

OptiFiber tester set up as follows:
Multimode module installed
Charged battery attached or the ac adapter
connected
Getting Started Testing Fiber
Tutorial: Running an OTDR Test
Job settings configured as follows (see the tutorial
"Preparing to Save Tests" on page 2-10 for
configuration steps):
START ID and STOP ID set to 03A-A01 and
03A-B06
A job folder with any name created on the
memory card
Your name as the operator
END 1 set to CLOSET; END 2 set to WORK
AREA
THIS END set to END 1
Fiber cabling to test: 50 m to 2 km (165 ft to 6500 ft) of
multimode fiber. If possible, select cabling that has a
connector somewhere along its length.
A launch fiber that matches the type of cable you will
test
Fiber cleaning supplies