Siemens SINUMERIK 840D Diagnostics Manual page 84

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

1 Alarms
8030
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
8032
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
8034
Definitions:
Reactions:
Remedy:
Program Continuation:
8036
Definitions:
Reactions:
1-84
Channel %1 block %2 option 'interpolation of more than 4 axes' not set
%1 = Channel number
%2 = Block number, label
The option for the number of interpolating axes does not correspond to the number of
axes programmed in the interpolation group.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Option: "Interpolation of more than 4 axes" (the number of axes that is then allowed can
be set in this option) or specify in the part program as many (or fewer, as required) axes
corresponding to the configuration of the control.
Clear alarm with the RESET key. Restart part program.
Option 'activation of more than %1 link axes' not set
%1 = Number of axes
The option for the number of link axes does not match the number of axes programmed in
MD $MN_AXCONF_LOGIC_MACHAX_TAB.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
• Buy option
• Configure fewer link axes
Clear alarm with the RESET key. Restart part program.
Option 'activation of axis containers' not set
The option for activating the axis container function in MD
$MN_AXCONF_LOGIC_MACHAX_TAB is not enabled.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
• Buy option
• Do not configure any containers
Clear alarm with the RESET key. Restart part program.
Option: it is not allowed to set different IPO cycles or position control cycles with
NCU link.
The option for activating the FAST_IPO_LINK has not been set. For NCU link, all Ipo or
position control cycles must then be equal (see FAST-IPO-LINK description).
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
10.04