1 Alarms
Definitions:
Reactions:
Remedy:
Program Continuation:
14751
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14752
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14753
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-222
More than 10 auxiliary functions have been programmed in an NC block.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Check whether all auxiliary functions are necessary in one block - modal functions need
not be repeated. Create separate auxiliary function block or divide the auxiliary functions
over several blocks.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 resources for motion synchronous actions not sufficient
(code: %3)
%1 = Channel number
%2 = Block number, label
%3 = Identifier
To process motion synchronous actions resources are required. They are configured via
the machine data $MC_MM_IPO_BUFFER_SIZE, $MC_MM_NUM_BLOCKS_IN_PREP
and $MC_MM_NUM_SYNC_ELEMENTS. If these resources are insufficient for executing
the part program, then this alarm is issued. The parameter %3 shows which resource has
run out:
Increase identifier <= 2: $MC_MM_IPO_BUFFER_SIZE or
$MC_MM_NUM_BLOCKS_IN_PREP.
Increase identifier > 2: $MC_MM_NUM_SYNC_ELEMENTS.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Correct part program or increase resources.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 DELDTG | STOPREOF conflict
%1 = Channel number
%2 = Block number, label
In a block of motion synchronous actions referring to a motion block, both DELDTG
(delete distance-to-go) and STOPREOF (preprocessing stop) have been programmed.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
The functions DELDTG and STOPREOF exclude each other in a block.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 motion synchronous actions with illegal interpolation type
%1 = Channel number
%2 = Block number, label
The active interpolation type (e.g. 5-axis interpolation) is not allowed for the motion syn-
chronous action or for the function "Several feeds".
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify part program.