10.04
Definitions:
Reactions:
Remedy:
Program Continuation:
4400
Definitions:
Reactions:
Remedy:
Program Continuation:
4402
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4502
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
MD 32410 JOG_AND_POS_JERK_ENABLE (jerk limitation) and MD 35240
ACCEL_TYPE_DRIVE (acceleration reduction) have been defined as the initial setting for
an axis. However, the two functions cannot be activated at the same time for one axis.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Resetting of 32410
JOG_AND_POS_JERK_ENABLE or 35240 ACCEL_TYPE_DRIVE.
Switch control OFF - ON.
MD alteration will cause reorganisation of buffered memory (loss of data!)
A machine data has been altered that configures the buffered memory. If the NCK powers
up with the altered data, this will lead to reorganization of the buffered memory and thus
to the loss of all buffered user data (part programs, tool data, GUD, leadscrew error com-
pensation, ...)
- Alarm display.
Please inform the authorized personnel/service department. If the control includes user
data that has not yet been saved, then a data backup must be performed before the next
NCK power-up. By manually resetting the altered MD to the value it had before the last
power-up, reorganization of the memory can be avoided.
Alarm display showing cause of alarm disappears. No further operator action necessary.
%1 causes a machine data reset
%1 = Machine data
If this machine data is set, the current machine data values are overwritten by the default
values at the next ramp-up. Under certain circumstances, this may cause data loss (even
in the buffered memory).
- Alarm display.
Please inform the authorized personnel/service department. If the control includes user
data that has not yet been saved, then a data backup must be performed before the next
NCK power-up. By manually resetting the altered MD to the value it had before the last
power-up, reorganization of the memory can be avoided.
Alarm display showing cause of alarm disappears. No further operator action necessary.
Channel %1 anachronism %2(%3) -> %4
%1 = Channel number
%2 = String: MD identifier
%3 = String: MD identifier
%4 = String: MD identifier
Previously, in $MC_RESET_MODE_MASK Bit4 and Bit5, the reset behavior of the 6th or
8th G group was determined. This setting is now made in $MC_GCODE_RESET_MODE.
In order to ensure compatible handling of "old" data backups, the "old" values are taken
from $MC_RESET_MODE_MASK and entered in $MC_GCODE_RESET_MODE.
- Alarm display.
--
Clear alarm with the Delete key or NC START.
1 Alarms