Siemens SINUMERIK 840D Diagnostics Manual page 486

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

1 Alarms
75604
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
75605
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
75606
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
75607
Parameters:
Definitions:
1-486
Channel %1 RESU: Return traveling not possible, error code %2
%1 = Channel number
%2 = Error code
Return traveling is not possible, as the following error was detected:
Error code = 1 : The current reverse block for return traveling is likely to be a block of
cc_resu_ini.spf or cc_resu_end.spf programmed with a block number. It is impermissible
to program block numbers in the subroutines cc_resu_ini.spf and cc_resu_end.spf, as
they have an internal meaning.
Error code = 2 : Unable to create cc_resu.mpf, as DRAM is insufficient.
Error code = 4 : The selected continuation block is likely to be a block of cc_resu_ini.spf or
cc_resu_end.spf programmed with block number. It is impermissible to program block
numbers in the subroutines cc_resu_ini.spf and cc_resu_end.spf, as they have an internal
meaning.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Error code = 1 or 4 : Remove all block numbers from cc_resu_ini.spf and cc_resu_end.spf
and their subroutines.
Error code = 2 : Assign a higher value to machine date
$MN_MM_DRAM_FILE_MEM_SIZE.
Clear alarm with the RESET key. Restart part program
Channel %1 RESU: internal error, error code %2
%1 = Channel number
%2 = Error code
With this alarm, RESU-internal error states are displayed which, together with the trans-
ferred error number, provide information on the error cause and error location.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
If this error occurs, please contact us on the SINUMERIK Hotline of the SIEMENS AG,
specifying the error number.
Clear alarm with the RESET key. Restart part program
Channel %1 RESU: retraceable contour was shortened
%1 = Channel number
The block search buffer is full. Therefore the retraceable contour had to be shortened.
- Alarm display.
This alarm has no effect on the current machining. If the alarm continues to occur fre-
quently, the reason should be eliminated: adjust machine data
$MC_RESU_RING_BUFFER_SIZE, $MC_RESU_SHARE_OF_CC_HEAP_MEM and
$MC_MM_NUM_CC_HEAP_MEM.
Clear alarm with the Delete key or NC START.
Channel %1 RESU: resynchronisation not possible
%1 = Channel number
The block search triggered by the compile cycle has been terminated with an error. It can
have the following cause: The control is not in the correct operating mode, e.g. in JOG_
AUTO instead of in AUTO.