1 Alarms
61247
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61248
Definitions:
Reactions:
Remedy:
Program Continuation:
61249
Definitions:
Reactions:
Remedy:
Program Continuation:
61250
Definitions:
Reactions:
Remedy:
Program Continuation:
61251
Definitions:
Reactions:
Remedy:
Program Continuation:
1-440
Channel %1 block %2: Blank radius too small
%1 = Channel number
%2 = Block number, label
-
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Increase blank radius.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2: Infeed too small
-
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Increase infeed.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2: Number of edges too small
-
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Increase number of edges.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2: Key width/Edge length too small
-
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Increase key width/edge length.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2: Key width/Edge length too large
-
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Decrease key width/edge length.
Clear alarm with the RESET key. Restart part program