Siemens SINUMERIK 840D Diagnostics Manual page 441

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
61252
Definitions:
Reactions:
Remedy:
Program Continuation:
61253
Definitions:
Reactions:
Remedy:
Program Continuation:
61254
Definitions:
Reactions:
Remedy:
Program Continuation:
61255
Definitions:
Reactions:
Remedy:
Program Continuation:
61257
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Channel %1 block %2: Chamfer/Radius too large
-
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Decrease chamfer/radius.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2: No finishing allowance programmed
No finishing allowance was entered.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Program a finishing allowance.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2: Error when traversing to fixed stop
-
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Specify another Z1 position for gripping the counterspindle.
Internal
Channel %1 block %2: Cut-off error: Tool breakage?
Cut-off could not be completely carried out.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Check the tool.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 Startup of counterspindle not complete
%1 = Channel number
%2 = Block number, label
-
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Check display MD 9803, 9851, 9852, 9853 and 9854.
Clear alarm with the RESET key. Restart part program