Siemens SINUMERIK 840D Diagnostics Manual page 240

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

1 Alarms
Definitions:
Reactions:
Remedy:
Program Continuation:
15186
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15190
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15300
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-240
Errors were found when processing initialization program _N_INITIAL_INI. This alarm will
also be output, if errors are found during editing of _N_INITIAL_INI in the GUD definition
files or if errors are found on ramp-up in the macro definition files.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department. Correct the INI or DEF file or
correct the MD and create a new INI file (via "Upload").
Switch control OFF - ON.
Channel %1 %2 errors in GUD, macro or INI file
%1 = Channel number
%2 = Number of detected errors
%2 errors were found when processing GUD/macro definition files (DEF files) or initializa-
tion files (INI files)
Alarm 15180 has already informed about the corresponding file.
Prior to that the errors shown were reported by error-specific alarms, e.g. 12080 "syntax
error".
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Modify definition file or initialization file
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 not enough free memory for subroutine call
%1 = Channel number
%2 = Block number, label
The following deadlock has been found in the interpreter: Memory is needed for calling a
subroutine. The module memory is, however, empty and there is no prospect of module
memory becoming free again by executing the preprocessing/main run queue, because
this queue is empty.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department. Increase machine data
28010 MM_NUM_REORG_LUD_MODULES/28040 MM_LUD_VALUES_MEM / 18210
MM_USER_MEM_DYNAMIC or program a preprocessing stop STOPRE before calling
the subroutine.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 invalid number-of-passed-blocks during block search
%1 = Channel number
%2 = Block number, label
In the function "Block search with calculation" a negative number of passes has been
entered in column P (number of passes). The permissible range of values is P 1 - P 9 999.
- Alarm display.
Enter only positive number of passes within the range of values.
Clear alarm with the Delete key or NC START.
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
10.04

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents