10.04
61344
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61345
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61346
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61347
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Channel %1 block %2 Several tools are active
%1 = Channel number
%2 = Block number, label channel number
-
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remove tool from another spindle.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 Parameterized D number (_KNUM) too large
%1 = Channel number
%2 = Block number, label channel number
-
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Reduce the D number in _KNUM, check software or MD of flat D number.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 Distance starting point/measuring point _SETV[0] and
_SETV[1] <= 0
%1 = Channel number
%2 = Block number, label channel number
The alarm is triggered by the following cycles: CYCLE961.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Parameters _SETV[0] or _SETV[1] are empty or smaller than 0.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 Angle 1st edge - 2nd edge equals 0
%1 = Channel number
%2 = Block number, label channel number
The alarm is triggered by the following cycles: CYCLE961.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Parameter _INCA equals 0.
Clear alarm with the RESET key. Restart part program