10.04
Definitions:
Reactions:
Remedy:
Program Continuation:
14119
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14120
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14122
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
With taper circumference interpolation of orientation, no end orientation has been pro-
grammed. The change of orientation is therefore not clearly defined.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 no intermediate orientation programmed
%1 = Channel number
%2 = Block number, label
With taper circumference interpolation of orientation with ORICONIO, an intermediate ori-
entation must also be programmed in addition to the end orientation.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 plane determination for programmed orientation not possible
%1 = Channel number
%2 = Block number, label
The programmed orientation vectors (direction vectors) in the beginning of block and end
of block point include an angle of 180 degrees. Therefore the interpolation plane cannot
be determined.
Example:
N50 TRAORI (1)
N55 A3=0 B3=0 C3=1
N60 A3=0 B3=0 C3=-1 ; the vector of this block is precisely opposite to that in the preced-
ing block.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify the part program so that the orientation vectors of a block are not directly opposed
to each other, for instance by dividing the block up into 2 subblocks.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 angle and direction of the cone programmed
%1 = Channel number
%2 = Block number, label
With taper circumference interpolation of orientation with ORICONCW and ORICC, only
the opening angle or the direction of the taper may be programmed. Programming of both
in one single block is not allowed.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.