Siemens SINUMERIK 840D Diagnostics Manual page 47

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
Reactions:
Remedy:
Program Continuation:
4181
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4182
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4183
Parameters:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Check machine data $MN_EXTERN_ M_NO_SET_INT and
$MN_EXTERN_M_NO_DISABLE_INT.
Switch control OFF - ON.
Channel %1 invalid assignment of an M auxiliary function number
%1 = Channel number
In machine data $MC_AUXFU_ASSOC_M0_VALUE or
$MC_AUXFU_ASSOC_M1_VALUE, a number has been specified for the configuration of
a new predefined M function which is occupied by the system, and cannot be used for an
assignment. (M0 to M5, M17, M30, M40 to M45).
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Configure an M function in machine data $MC_AUXFU_ASSOC_M0_VALUE or
$MC_AUXFU_ASSOC_M1_VALUE which is not occupied by the system (M1 to M5, M17,
M30, M40 to M45).
Switch control OFF - ON.
Channel %1 invalid M auxiliary function number in %2%3, MD reset
%1 = Channel number
%2 = MD identifier
%3 = If required, MD index
In the specified machine data, a number has been specified for the configuration of an M
function which is occupied by the system, and cannot be used for an assignment. (M0 to
M5, M17, M30, M40 to M45 and also M98, M99 with applied ISO dialect). The value set
by the user has been reset to the default value by the system.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Configure an M function in the specified machine data which is not occupied by the sys-
tem (M0 to M5, M17, M30, M40 to M45 and also M98, M99 with applied ISO dialect).
Clear alarm with the RESET key. Restart part program
Channel %1 M auxiliary function number %2 used several times (%3 and %4)
%1 = Channel number
%2 = M auxiliary function number
%3 = MD identifier
%4 = MD identifier
1 Alarms
1-47