10.04
Definitions:
Reactions:
Remedy:
Program Continuation:
14413
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14414
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14415
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
It is not permissible to change the assignment of geometry axes to channel axes when
transformation is active.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 fine tool correction: changeover geometry/channel axis not
allowed
%1 = Channel number
%2 = Block number, label
It is not permissible to change the assignment of geometry axes to channel axes during
active tool fine compensation.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 GEOAX function: incorrect call
%1 = Channel number
%2 = Block number, label
The parameters for the GEOAX(...) call are incorrect. Possible causes:
• Uneven number of parameters.
• More than 6 parameters were specified.
• A geometry axis number was programmed which was smaller than 0 or greater than 3.
• A geometry number was programmed more than once.
• An axis identifier was programmed more than once.
• An attempt was made to assign a channel axis to a geometry axis which has the same
name as one of the channel axes.
• An attempt was made to remove a geometry axis from the geometry axis grouping and
the geometry axis has the same name as one of the channel axes.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify part program or correction block.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 tangent control: changeover geometry/channel axis not
allowed
%1 = Channel number
%2 = Block number, label
An assignment change of the geometry axes to channel axes is not permitted with active
tangential control.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Change part program and delete active tangential control with TANGDEL.
Clear alarm with NC START or RESET key and continue the program.