Siemens SINUMERIK 840D Diagnostics Manual page 281

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
Remedy:
Program Continuation:
16951
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16952
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16953
Parameters:
Definitions:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
$MN_SUPPRESS_ALARM_MASK $MC_AUTO_IPTR_LOCK and language command
IPTRLOCK
Clear alarm with the Delete key or NC START.
Channel %1 search run in a program section that cannot be searched
%1 = Channel ID
With the language commands IPTRLOCK and IPTRUNLOCK, the part programmer can
identify part program sections that cannot be searched. Every search run in these
program sections will be acknowledged with alarm 16951.
In other words:
When the alarm appears, the user has started a search run (Serupro type)
and the search target lies in an area that cannot be searched!
An area that cannot be searched can also be defined implicitly with the machine data
$MC_AUTO_IPTR_LOCK.
Note:
The alarm can only be generated when the simulation is
completed during the search run. The alarm cannot
be output immediately at the start of the search run.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
$MN_SUPPRESS_ALARM_MASK $MC_AUTO_IPTR_LOCK and language command
IPTRLOCK
Clear alarm with the RESET key. Restart part program
Channel %1 start program command not possible due to MDA
%1 = Channel ID
NCK is currently executing an ASUB in MDA mode. In this constellation,
parts program command "Start" is not allowed for another channel.
Attention: If an asup is started from JOG, the NCK can internally change to MDA,
if the NCK was previously in MDA and not in RESET.
Note: Without this alarm, the MDA buffer of the other channel would always be started.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Start ASUB in AUTO or ->JOG in AUTO
Clear alarm with the RESET key. Restart part program
Channel %1 For slave axis %2 SERUPRO not allowed, as master axis %3 not sub-
ject to axis/spindle disable
%1 = Channel number
%2 = Slave axis name, following spindle number
%3 = Master axis name, master spindle number
Currently, the alarm occurs only in combination with the SERUPRO action. SERUPRO
stands for search via program test.
SERUPRO is possible only with an active coupling, if the axis/spindle disable is active for
all master axes/spindles of the slave axis/spindle
1 Alarms
1-281

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents