Siemens SINUMERIK 840D Diagnostics Manual page 270

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

1 Alarms
Definitions:
Reactions:
Remedy:
Program Continuation:
16913
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16914
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16915
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16916
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-270
This action can only be performed in Reset state.
Example: Program selection through MMC or channel communication (INIT) can only be
performed in Reset state.
- Alarm display.
Reset or wait until processing is terminated.
Clear alarm with the Delete key or NC START.
Mode group %1 channel %2 mode change: action %3<ALNX> not allowed
%1 = Channel number
%2 = Mode group number
%3 = Action number/action name
The change to the desired mode is not permitted. The change can only take place in the
Reset state.
Example: Program processing is halted in AUTO mode by NC Stop. Then there is a mode
change to JOG mode (program status interrupted). From this operating mode it is only
possible to change to AUTO mode and not to MDA mode!
- Alarm display.
Either activate the Reset key to reset program processing, or activate the mode in which
the program was being processed previously.
Clear alarm with the Delete key or NC START.
Mode group %1 channel %2 mode change: action %3<ALNX> not allowed
%1 = Channel number
%2 = Mode group number
%3 = Action number/action name
Incorrect mode change, e.g.: Auto -> MDAREF.
- Alarm display.
Check operation or selected mode.
Clear alarm with the Delete key or NC START.
Channel %1 action %2<ALNX> not allowed in the current block
%1 = Channel number
%2 = Action number/action name
If traversing blocks are interrupted by asynchronous subroutines, then it must be possible
for the interrupted program to continue (reorganization of block processing) after termina-
tion of the asynchronous subroutine.
The 2nd parameter describes which action wanted to interrupt block processing.
- Alarm display.
Let the program continue to a reorganized NC block or modify part program.
Clear alarm with the Delete key or NC START.
Channel %1 repositioning: action %2<ALNX> not allowed in the current state
%1 = Channel number
%2 = Action number/action name
Repositioning of block processing presently not possible. In certain cases this can prevent
a mode change from taking place.
The 2nd parameter describes which action should be used to perform repositioning.
- Alarm display.
Let the program continue to a repositioned NC block or modify part program.
Clear alarm with the Delete key or NC START.
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
10.04

Hide quick links:

Advertisement

Table of Contents
loading