Advertisement

1 Alarms
Remedy:
Program Continuation:
300715
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
300716
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
300717
Parameters:
Definitions:
1-570
Please inform the authorized personnel/service department. Delete modified machine
data (e.g. controller data). Reset the drive (delete the bootfile) and repeat the startup.
Switch control OFF - ON.
Axis %1 drive %2 maximum power section current less than or equal to zero
%1 = NC axis number
%2 = Drive number
The maximum current of the power section entered in drive MD 1107:
$MD_INVERTER_MAX_CURRENT (transistor limit current) is less than or equal to zero.
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Reset the drive (delete the
bootfile) and repeat the startup.
Switch control OFF - ON.
Axis %1 drive %2 torque constant less than or equal to zero
%1 = NC axis number
%2 = Drive number
1. The value in drive MD 1113: $MD_TORQUE_CURRENT_RATIO (torque constant) is
less than or equal to zero.
2. The ratio of MD1113: $MD_TORQUE_CURRENT_RATIO (torque constant) / MD1112:
$MD_NUM_POLE_PAIRS (motor pole pairs) is greater than 70.
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department.
For standard motors: Reset the drive (delete the bootfile) and repeat the startup.
For third-party motors: Enter a valid value in drive MD 1113:
$MD_TORQUE_CURRENT_RATIO (torque constant), or check and, if necessary, correct
the ratio of MD1113: $MD_TORQUE_CURRENT_RATIO (torque constant) / MD1112:
$MD_NUM_POLE_PAIRS (motor pole pairs).
Switch control OFF - ON.
Axis %1 drive %2 motor moment of inertia less than or equal to zero
%1 = NC axis number
%2 = Drive number
The value in MD 1117: $MD_MOTOR_INERTIA (motor moment of inertia) is less than or
equal to zero.
 Siemens AG, 2004. All rights reserved