10.04
Definitions:
Reactions:
Remedy:
Program Continuation:
300402
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
300403
Parameters:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Either there is no software for this drive type or it contains errors.
Drive type
• 1 = VSA (as in MD DRIVE_TYPE!)
• 2 = HSA
• 3 = SLM
• 4 = HYD
• 5 = ANA
Block number
• 1 = Drive software (code)
• 2 = Data descriptions (ACC file)
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Check the data carrier (Jeida
board), replace if necessary.
Clear alarm with the RESET key in all channels. Restart part program.
System error in drive link. Error codes %1, %2
%1 = Error code 1
%2 = Error code 2
An internal software error or serious error condition has occurred which may be recover-
able by hardware reset. Troubleshooting can generally be performed only by Siemens
AG, System Support for A&D MC Products, Hotline (tel.: see alarm 1000).
In the error code combination (324,26), the calculation time allocation for the drive com-
munication subtask should be increased via the MD 10140
$MN_TIME_LIMIT_NETTO_DRIVE_TASK (possible up to 500 ms).
If the above-mentioned limit is exhausted and the alarm continues to occur, the MD 10150
$MN_PREP_DRIVE_TASK_CYCLE_RATIO=1 can be set additionally. Please note that
by reducing MD 10150, the time share of the preparation in the non-cyclic time plane is
reduced. This may lead to longer block cycle times.
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000).
Switch control OFF - ON.
Axis %1 drive %2 drive software and drive MD with different version numbers
%1 = NC axis number
%2 = Drive number
1 Alarms