Siemens SINUMERIK 840D Diagnostics Manual page 41

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
Reactions:
Remedy:
Program Continuation:
4073
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4075
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4076
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4077
Parameters:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
- Alarm display.
Please inform the authorized personnel/service department.
Clear alarm with the Delete key or NC START.
Compile cycle functions define machine data number %1 several times
%1 = Machine data number
Can only occur when installing compile cycle functions. Two different compile cycle appli-
cations use the same machine data number. The machine data which was defined twice
is shifted into the free number range above 64000.
- Alarm display.
The error has no effect on the usability of the machine data and the function of the com-
pile cycle application. To ensure that the compile cycle machine data documentation is
correct, you must contact the supplier of the compile cycle. Only the supplier can remedy
the error by changing the software.
Switch control OFF - ON.
Machine data %1 (and maybe others) not altered due to missing permission level
%2
%1 = String: MD identifier
%2 = Write protection level of the MD
On executing a TOA file or when writing data from the part program, an attempt has been
made to write an item of data with a higher protection level than the access authorization
currently set in the control. The item of data in question has not been written and program
execution is continued. This alarm is set only when access violation is detected for the
first time.
- Alarm display.
Please inform the authorized personnel/service department. Set the required access level
by means of keyswitch or password entry or delete the machine data concerned from the
MD file/part program.
Clear alarm with the Delete key or NC START.
%1 Machine data could not be altered with permission level %2
%1 = Number of MDs
%2 = Preset access authorization
On executing a TOA file or when writing data from the part program an attempt has been
made to write data with a higher protection level than the access authorization currently
set in the control. The data in question have not been written and program execution is
continued without hindrance. This alarm is issued on acknowledging the alarm
EXBSAL_MD_PERMISSION_DENIED. It can be cleared only with Power On.
- NC Start disable in this channel.
- Alarm display.
Please inform the authorized personnel/service department. Set the required access level
by means of keyswitch or password entry or delete the machine data concerned from the
MD file/part program.
Switch control OFF - ON.
New value %1 of MD %2 not set. Requested %3 bytes too much %4 memory.
%1 = New value of machine data
%2 = Machine data number
%3 = Number of bytes requested that exceeded availability
%4 = Type of memory
1 Alarms
1-41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents