1 Alarms
Remedy:
Program Continuation:
12500
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12510
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-158
Press the NC Stop key and select the function "Correction block" with the softkey PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block.
• Use the REDEF instruction only in the INITIAL_INI block
• Using the operator panel, set the current protection level to at least the same level as
that of the variable with the highest level
• Program protection level within the permissible value range
• Only program new protection levels that are lower than the old values
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 in this module %3 is not possible
%1 = Channel number
%2 = Block number, label
%3 = Source string
The displayed keyword may not be used in this type of block and at this location (all files
in the NCK are designated as blocks).
Block types:
Program block
Contains a main program or subroutine
Data block
Contains macro or variable definitions and possibly an M, H or E function
Initialization block
Contains only selected language elements for data initialization
- Correction block
- Interface signals are set.
- Alarm display.
Press the NC Stop key and select the function "Correction block" with the softkey PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block.
Remove the displayed language elements (keyword) with its parameters from this block
and insert in the block provided for this purpose.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 too many machine data %3
%1 = Channel number
%2 = Block number, label
%3 = Source symbol
In the part program, in the machine data file (..._TEA) and in the initialization file (..._INI),
no more than 2 machine data may be used per block.
Example:
N ...
N 100 $MN_OVR_FACTOR_FEEDRATE [10] = 15,
$MN_OVR_FACTOR_FEEDRATE [11] = 20
N ...
- Correction block
- Interface signals are set.
- Alarm display.
Press the NC Stop key and select the function "Correction block" with the softkey PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block.
• Divide up the part program block into several blocks.
• If necessary, use the local variable for storing intermediate results.
Clear alarm with NC START or RESET key and continue the program.