Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12261
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12270
Parameters:
Definitions:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Channel %1 block %2 too many initialization values specified %3
%1 = Channel number
%2 = Block number, label
%3 = Source string
In the initialization of an array (array definition and value assignments to individual array
elements) there are more initialization values than array elements. Example: N10 DEF
INT OTTO[2,3]=(..., ..., {more than 6 values})
- Correction block
- Interface signals are set.
- Alarm display.
Press the NC Stop key and select the function "Correction block" with the softkey PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block.
Check the NC program to establish whether:
1. During array definition the number of array elements (n,m) was indicated correctly
(DEF INT FIELDNAME[n,m] e.g. an array with 2 lines and 3 columns: n=2, m=3). 2. Dur-
ing initialization the value assignments have been made correctly (values of the individual
field elements separated by comma, decimal point for variables of the type REAL).
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 initialization of %3 not allowed
%1 = Channel number
%2 = Block number, label
%3 = Source string
Frame type variables cannot be initialized in the definition. Example: DEF FRAME LOC-
FRAME = CTRANS(X,200)
Equally, no default values can be programmed for axes in the program run when initializ-
ing fields by SET.
- Correction block
- Interface signals are set.
- Alarm display.
IPerform initialization in separate block in the execution part of the program: DEF FRAME
LOCFRAME LOCFRAME = CTRANS(X,200)
When using for axis variables:
Replace DEF AXIS AXIS_VAR [10] AXIS_VAR [5] = SET (X, , Y) by: DEF AXIS
AXIS_VAR [10] AXIS_VAR [5] = X AXIS_VAR [7] = Y
If REDEF ... INIRE, INIPO, INICF, PRLOC changes the behavior of a GUD, LUD etc.,
then the machine data $MN_DEFAULT_VALUES_MEM_MASK must equal 1.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 macro identifier %3 already defined
%1 = Channel number
%2 = Block number, label
%3 = Source string macro name
The name of the macro to be selected by the instruction DEFINE is already defined in the
control as:
Macro name
Keyword
Variable
Configured identifier.