Example: An interrupt interrupts the current program processing. Other interrupts with
higher priorities interrupt processing of the previously activated asynchronous subrou-
tines.
Possible actions are: DryRunOn/Off, DecodeSingleBlockOn, delete distance-to-go, inter-
rupts .....
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Do not trigger the event on this block.
Clear alarm with the RESET key. Restart part program
Channel %1 program control: action %2<ALNX> not allowed in the current state
%1 = Channel number
%2 = Action number/action name
The current processing cannot be stopped, due to an active preprocessing process. This
applies to, for example, loading machine data and block searches until the search object
is found.
- Interface signals are set.
- Alarm display.
Abort by pressing Reset!
Clear alarm with the Delete key or NC START.
Channel %1 caution: program test modifies tool management data
%1 = Channel number
Tool management data is changed during program testing. It is not possible to automati-
cally rectify the data after termination of the program testing.
This error message prompts the user to make a backup copy of the data or to reimport the
data after the operation is terminated.
- Alarm display.
Please inform the authorized personnel/service department. Save tool data on MMC and
reimport data after "ProgtestOff".
Clear alarm with the Delete key or NC START.
Channel %1 program control: action %2<ALNX> not allowed in the current state,
action %3<ALNX> active
%1 = Channel number
%2 = Action number/action name
%3 = Action number/action name
The action has been refused since a mode or sub-mode change (change to automatic
mode, MDA, JOG, overstoring, digitizing, etc.) is taking place.
Example: This alarm message is output if the Start key is pressed during a mode or sub-
mode change from, for example, automatic to MDA, before the NCK has confirmed selec-
tion of the mode.
- Alarm display.
Repeat action.
Clear alarm with the Delete key or NC START.