18004
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
18005
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
18006
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
18100
Parameters:
1-306
Channel %1 block %2 orientation of workpiece-related protection zone %3 does not
correspond to the orientation of tool-related protection zone %4
%1 = Channel number
%2 = Block number, label
%3 = Number of workpiece-related protection zone
The orientation of the workpiece-related protection zone and the orientation of the tool-
related protection zone differ. If the protection zone number is negative, then this is a glo-
bal protection zone.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
• Modify the protection zone definition or do not simultaneously activate protection zones
that have different orientations.
• Check machine data and modify the protection zone definition if necessary.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 serious error in definition of NCK-specific protection zone
%3
%1 = Channel number
%2 = Block number, label
%3 = Protection zone number
The protection zone definition must be terminated with EXECUTE before a preprocessing
stop is performed. This also applies to any that are initiated implicitly such as with G74,
M30, M17.
- Correction block is reorganized.
- Local alarm reaction.
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 serious error in definition of channel-specific protection zone
%3
%1 = Channel number
%2 = Block number, label
%3 = Protection zone number
The protection zone definition must be terminated with EXECUTE before a preprocessing
stop is performed. This also applies to any that are initiated implicitly such as with G74,
M30, M17.
- Correction block is reorganized.
- Local alarm reaction.
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 invalid value assigned to FXS[]
%1 = Channel number
%2 = Block number, label
 Siemens AG, 2004. All rights reserved