10.04
Program Continuation:
14098
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14099
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14100
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
10 000: AXCONF_MACHAX_NAME_TAB
20 070: AXCONF_GEOAX_NAME_TAB
20 080: AXCONF_CHANAX_NAME_TAB
Select the transfer string in accordance with the axis name and change the axis name in
the machine data if necessary. (If a change of name is to take place via the NC part pro-
gram, this change must first be validated by means of a "Power On").
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 conversion error: no valid number found
%1 = Channel number
%2 = Block number, label
The string is not a valid INT or REAL number.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Modify part program. If it is an entry, then you can check whether the string is a number
via the preset function ISNUMBER (with the same parameter).
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 result in string concatenation too long
%1 = Channel number
%2 = Block number, label
The result of string chaining returns a string which is greater than the maximum string
length laid down by the system.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Adapt part program. With the function STRLEN, it is also possible to test the size of the
sum string before performing the chaining operation.
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 orientation transformation not available
%1 = Channel number
%2 = Block number, label
Four transformation groupings (transformation types) can be set for each channel via
machine data. If the keyword TRAORI(n) (n ... number of the transformation grouping) is
used to address a transformation grouping for which the machine data is not defaulted,
the alarm message will be triggered.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Press the NC Stop key and select the function "Correction block" with the softkey PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block.
• Check the number of the transformation grouping when calling the part program with the
keyword TRAORI(n) (n ... number of the transformation grouping).
• Enter the machine data for this transformation grouping and then activate by "Power
On".
Clear alarm with NC START or RESET key and continue the program.