Siemens SINUMERIK 840D Diagnostics Manual page 193

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
14129
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14130
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14131
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14132
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14133
Parameters:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Channel %1 block %2 orientation angles and orientation vector components pro-
grammed
%1 = Channel number
%2 = Block number, label
An orientation angle and components of an orientation vector were programmed at the
same time.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 too many initialization values given
%1 = Channel number
%2 = Block number, label
On assigning an array by means of SET, more initialization values than existing array ele-
ments have been specified in the program run.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Reduce the number of initialization values.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 orientation axes and lead/tilt angles programmed
%1 = Channel number
%2 = Block number, label
An orientation angle and a leading or sideways angle were programmed at the same time.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 orientation axes incorrectly configured
%1 = Channel number
%2 = Block number, label
The configuration of the orientation axes does not match the machine kinematics. Also,
for example, when the position measuring system has not been set for the rotary axes.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Adapt machine data.
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 G code for orientation definition not allowed
%1 = Channel number
%2 = Block number, label
1 Alarms
1-193

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents