Specification Of Circuit Breaker And Fuse - Delta ASD-B2-1521-F User Manual

Asda-b2 series
Hide thumbs Also See for ASD-B2-1521-F:
Table of Contents

Advertisement

ASDA-B2
(2) Reduce the acceleration and deceleration of the work cycle to lower the motor
load.
(3) Apply external forced air cooling to the servo motor using cooling fans or other
means.
Note: do not place a gasket or other insulating materials between the servo motor and
heat sink, as this may result in motor temperature increase, noise resistance being
affected, and motor malfunction.

2.5 Specification of Circuit Breaker and Fuse

Caution: Please use the fuse and circuit breaker that is recognized by UL/CSA.
Servo Drive Model
Operation Mode
ASD-B2-0121-B
ASD-B2-0221-B
ASD-B2-0421-B
ASD-B2-0721-B
ASD-B2-1021-B
ASD-B2-1521-B
ASD-B2-2023-B
ASD-B2-3023-B
If the servo drive equips with earth leakage circuit breaker for avoiding
NOTE
electric leakage, please choose the current sensitivity which is over
200mA and can continue up to 0.1 seconds.
Revision May, 2018
Circuit Breaker
General
5A
5A
10A
10A
15A
20A
30A
30A
Chapter 2 Installation
Fuse (Class T)
General
5A
6A
10A
20A
25A
40A
50A
70A
2-9