2.5 Specification of Circuit Breaker and Fuse
Caution: Please use the fuse and circuit breaker that is recognized by UL/CSA.
Servo Drive Model
Operation Mode
ASD-M-0721-
ASD-M-1521-
If the servo drive equips with earth leakage circuit breaker for avoiding
electric leakage, please choose the current sensitivity which is over
NOTE
200mA and can continue up to 0.1 seconds.
2.6 EMI Filters Selection
Item
Power
1
750W
2
1500W
EMI Filter Installation
All electronic equipment (including servo drive) generates high or low frequency noise
during operation and interfere the peripheral equipments via conduction or radiation. With
EMI Filter and the correct installation, much interference can be eliminated.
When installing servo drive and EMI Filter, please follow the instructions of the user manual
and make sure it meets the following specification.
1. EN61000-6-4 (2001)
2. EN61800-3 (2004) PDS of category C2
3. EN55011+A2 (2007) Class A Group 1
Revision December, 2014
Circuit breaker
General
30A
70A
Servo Drive Model
ASD-M-0721-
ASD-M-1521-
Chapter 2 Installation
Fuse (Class T)
General
50A
140A
EMI Filter Model
20TDT1W4D
20TDT1W4D
FootPrint
N
N
2-5