Cia 402 Drive Profile; State Machine Control Of The Servo Amplifier; Function Description - Mitsubishi Electric MR-JE-*C Instruction Manual

General purpose ac servo melservo-je ethernet interface servo amplifier
Hide thumbs Also See for MR-JE-*C:
Table of Contents

Advertisement

5. CiA 402 DRIVE PROFILE

5. CiA 402 DRIVE PROFILE
This chapter describes how to drive a servo motor in the communication. For MR-JE-_C servo amplifier,
objects/registers are assigned according to Index of the CiA 402 drive profile. By accessing the assigned
objects/registers, the controller can drive the servo motor.

5.1 State machine control of the servo amplifier

5.1.1 Function description

The servo amplifier status is managed based on the state machine below. Setting the control command
(6040h) from the master station (controller) changes the status of the slave stations (servo amplifiers). The
current servo amplifier status can be read with the control status (6041h).
Servo initialization
in process
In wait for forced stop
reset
In wait for main
circuit charging
(ready-off)
(12)
Drive standby
(servo-off)
Forced stop
deceleration
(F) Quick stop active
Transition by slave
Transition by master
Transition by slave or master
POINT
The following are shown in the "Access" in this instruction manual.
"ro": Only reading is available.
"wo": Only writing is available.
"rw": Reading and writing are available.
Power on
(0)
(A) Not ready to switch on
(1)
(B) Switch on disabled
(2)
(10)
(C) Ready to switch on
(3)
(D) Switched on
(4)
(16)
(E) Operation enabled
(11)
In normal drive
(servo-on)
(15)
(H) Fault
(7)
(6)
(8)
(9)
(5)
(G) Fault reaction active
(13)
Error occurs
5 - 1
Ready-off/Servo-off
(During main circuit
charging)
Occurrence of
alarm
(14)
Ready-off/Servo-off
(Main circuit charging
completed)
Ready-on/Servo-on
Alarm handling in process
(forced stop deceleration, alarm
history writing, and alarm display
change)

Hide quick links: