Mitsubishi Electric MR-JE-*C Instruction Manual page 268

General purpose ac servo melservo-je ethernet interface servo amplifier
Hide thumbs Also See for MR-JE-*C:
Table of Contents

Advertisement

12. WHEN USING WITH A GENERAL-PURPOSE INTERFACE
(b) Point table
1) Point table setting
Point tables 1 to 255 can be set. To use point tables No. 4 to 255, enable DI2 (Point table No.
selection 3) to DI7 (Point table No. selection 8) with "Device Setting" on MR Configurator2.
Set point tables using MR Configurator2 or the operation section of the servo amplifier.
The following shows the main descriptions to be set. Refer to section 12.5.2 (2) for details of the
settings.
Item
Position data
Servo motor
speed
Acceleration time
constant
Deceleration time
constant
Dwell
Auxiliary function Set when performing automatic continuous operation.
M code
2) Point table selection
Using the input signal or the communication function, select the point table No. with the
communication command from the controller, such as a personal computer.
The following table shows the point table No. selected in response to the input signal and the
communication command.
However, when using the input signal to select the point table No., you can only use point table
No. 1 to 3 in the initial status.
To use point table No. 4 to 255, enable input signals DI2 (Point table No. selection 3) to DI7
(Point table No. selection 8) with "Device Setting" on MR Configurator2.
When using the communication function to select the point table No., refer to chapter 7.
DI7
DI6
0
0
0
0
0
0
0
0
0
0
1
1
1
1
Note. 0: Off
1: On
Set the position data for movement.
Set the command speed of the servo motor for execution of positioning.
Set the acceleration time constant.
Set the deceleration time constant.
Set the waiting time when performing automatic continuous operation.
The first digit and the second digit of the M code are outputted in 4-bit binary
respectively.
Input signal (Note)
DI5
DI4
0
0
0
0
0
0
0
0
0
0
1
1
1
1
Main description
DI3
DI2
DI1
0
0
0
0
0
0
0
0
0
1
1
1
1
1
12 - 53
Point table No. to be
selected
DI0
0 (for home position
0
0
return)
0
1
1
0
1
1
0
0
1
0
1
1
1
2
3
4
254
255