Mitsubishi Electric MR-JE-*C Instruction Manual page 202

General purpose ac servo melservo-je ethernet interface servo amplifier
Hide thumbs Also See for MR-JE-*C:
Table of Contents

Advertisement

9. HOW TO USE JOG MODE
(3) Manual pulse generator multiplication
(a) Setting with object/register
Set bit 4 (C_TP0) of Control DI7 (2D07h) and bit 5 (C_TP1) of Control DI7.
C_TP1 (Manual pulse
generator
multiplication 2)
(Note)
0
0
1
1
Note. 0: Off
1: On
(b) Setting with a parameter
Using [Pr. PT03], set the servo motor rotation multiplication to the rotation amount of the manual
pulse generator.
[Pr. PT03] setting
_ _ 0 _
_ _ 1 _
_ _ 2 _
(4) Operation
Turning the manual pulse generator rotates the servo motor. For the rotation direction of the servo
motor, refer to (2) in this section. When the manual pulse generator is turned during a JOG operation,
the commands inputted from the manual pulse generator are adjusted by the commands of JOG
operation.
C_TP0 (Manual pulse
Servo motor rotation multiplication
generator
to manual pulse generator rotation
multiplication 1)
(Note)
0
[Pr. PT03] setting enabled
1
0
1
Servo motor rotation multiplication to manual pulse
generator rotation amount
× 1
× 10
× 100
amount
× 1
× 10
× 100
9 - 11
Travel distance
[mm]
[inch]
[pulse]
0.001
0.0001
1
0.01
0.001
10
0.1
0.01
100
Travel distance
[mm]
[inch]
[pulse]
0.001
0.0001
1
0.01
0.001
10
0.1
0.01
100