12. WHEN USING WITH A GENERAL-PURPOSE INTERFACE
(c) Manual pulse generator multiplication
1) Using the input signals (devices) for setting
In "Device setting" of MR Configurator2, set TP0 (Manual pulse generator multiplication 1) and
TP1 (Manual pulse generator multiplication 2) for input signals.
TP1 (Manual pulse
generator
multiplication 2)
(Note)
0
0
1
1
Note. 0: Off
1: On
2) Setting with parameter
Using [Pr. PT03], set the servo motor rotation multiplication to the rotation amount of the manual
pulse generator.
[Pr. PT03] setting
_ _ 0 _
_ _ 1 _
_ _ 2 _
(d) Operation
Turning the manual pulse generator rotates the servo motor. For the rotation direction of the servo
motor, refer to (2) (b) in this section. When the manual pulse generator is turned during a JOG
operation, the commands inputted from the manual pulse generator are adjusted by the commands
of JOG operation.
TP0 (Manual pulse
Servo motor rotation multiplication
generator
to manual pulse generator rotation
multiplication 1)
(Note)
0
[Pr. PT03] setting enabled
1
0
1
Servo motor rotation multiplication to manual pulse
generator rotation amount
× 1
10 times
100 times
12 - 69
amount
[mm]
× 1
0.001
10 times
0.01
100 times
0.1
[mm]
0.001
0.01
0.1
Travel distance
[inch]
[pulse]
0.0001
1
0.001
10
0.01
100
Travel distance
[inch]
[pulse]
0.0001
1
0.001
10
0.01
100